EMISSIONS · IMMUNITY · PRODUCT COMPLIANCE

Accredited EMC Testing Laboratory

Stancer Testing-Lab provides electromagnetic compatibility (EMC) testing services for manufacturers developing products for international markets. We evaluate emissions and immunity for electrical and electronic products, helping your team identify applicable requirements, prepare representative test configurations and obtain documented results. Our EMC testing laboratory is located in Laval, Quebec.

Our A2LA accreditation to ISO/IEC 17025:2017, certificate 7352.01, covers defined EMC and radio test methods. We agree the relevant product standards, test conditions and reporting requirements before your equipment arrives.

Discuss Your EMC Testing Requirements Review Our Accreditation

Chamber and equipment for electromagnetic compatibility testing
Controlled emissions and immunity measurements for electrical and electronic equipment.

EMC Testing Services: Emissions & Immunity

Emissions testing measures electromagnetic interference (EMI) produced by your equipment. Immunity testing evaluates whether it continues to function as required when exposed to specified disturbances. An EMC compliance testing program brings together the relevant evaluations for your product, intended environment, ports and destination markets.

Radiated & Conducted RF Immunity

Controlled RF exposure assesses the equipment’s response while agreed functions are monitored. Explore radiated immunity and conducted immunity.

ESD, Burst & Surge

Electrical disturbances can produce resets, communication errors or other functional responses. We apply the selected methods and record behaviour against the agreed criteria. Explore ESD testing and transient testing.

Product Standards in Our Accreditation Scope

A product or product-family standard establishes the requirements for a particular category. It may call up several basic test methods. The references below are selected examples from Stancer’s scope; the applicable edition and configuration are confirmed for your project.

For industrial, scientific and medical equipment, CISPR 11 and EN 55011 address emissions within their respective applicability. Multimedia equipment EMC testing can combine CISPR 32 / EN 55032 emissions with CISPR 35 / EN 55035 immunity. Measurement, control and laboratory equipment is evaluated using IEC 61326-1 and relevant listed parts of IEC 61326-2. We check the product classification and intended environment before selecting the requirements.

Examples of product and product-family coverage
Product / applicationSelected scope references
Industrial, scientific and medical equipmentCISPR 11; BS EN/EN 55011
Multimedia equipmentCISPR 32 / BS EN/EN 55032 emissions; CISPR 35 / BS EN/EN 55035 immunity
Medical electrical equipmentIEC 60601-1-2; BS EN/EN 60601-1-2
Measurement, control and laboratory equipmentIEC 61326-1 and listed IEC 61326-2 methods
Automotive vehicles and componentsCISPR 12; CISPR 25 clauses 6.3, 6.4 and 6.5; listed ISO automotive methods; ECE Regulation 10
Radio equipment EMCListed EN 301 489 parts
North American emissions requirementsFCC Part 15 Subpart B; listed ICES requirements including ICES-003

See our dedicated medical device EMC, automotive EMC and RF and wireless testing pages for application-specific programs.

Basic EMC Test Methods

Basic methods describe how a disturbance is measured or applied. They do not, on their own, determine every requirement for the finished product.

Selected immunity and power-quality methods
EvaluationIEC reference
Electrostatic dischargeIEC 61000-4-2
Radiated RF immunityIEC 61000-4-3
Electrical fast transients / burstIEC 61000-4-4
Surge immunityIEC 61000-4-5
Conducted RF immunityIEC 61000-4-6
Power-frequency magnetic-field immunityIEC 61000-4-8
AC voltage dips, interruptions and variationsIEC 61000-4-11
DC voltage dips, interruptions and variationsIEC 61000-4-29
Harmonic current emissionsIEC 61000-3-2; IEC 61000-3-12
Voltage fluctuations and flickerIEC 61000-3-3; IEC 61000-3-11

A Laboratory Equipped for Practical Test Setups

Our dome-shaped SAC PLUS semi-anechoic chamber offers usable dimensions of 8.5 × 5 × 6 m, a 2 × 2 m door and EUT capacity up to 2,000 kg. An automated antenna tower and turntable use Rohde & Schwarz ELEKTRA and dedicated control systems.

Instrumentation includes a Rohde & Schwarz ESW receiver with coverage to 44 GHz, RF signal generators, high-power amplifiers across applicable bands up to 6 GHz, LISNs, power meters, antennas, transient generators and harmonic/flicker systems.

Applicable setups support 200 A, three-phase EUT current and RF immunity fields up to 200 V/m. These are maximum capabilities, not levels available for every method or frequency. Specialist RF measurement arrangements extend to 325 GHz; the selected test program identifies the usable range and accredited activities.

The chamber uses site-performance verification for NSA, field uniformity and sVSWR as applicable. An RFI trap supports cable feedthroughs, while built-in filtering and additional setup filtering can help control external conducted noise. Explore the chamber and laboratory capabilities.

From Requirements Review to a Documented Test Report

  1. Establish the requirements. Share the product, intended environment, target markets and customer specifications. We identify the applicable methods and agree the program.
  2. Prepare the configuration. Confirm samples, accessories, cable arrangements, operating modes, loads and functional monitoring.
  3. Investigate early if needed. Pre-compliance testing helps locate emissions sources or immunity weaknesses before formal testing.
  4. Perform the agreed tests. Measurements and disturbance responses are recorded against the selected limits and acceptance criteria.
  5. Document the results. The report identifies the tested equipment, configuration, methods, conditions, results and relevant deviations.

EMC Test Preparation: What to Send Before Booking

Provide a product description, dimensions, mass, supply voltage and current, operating modes, cable and port information, accessories, firmware version, target markets and requested schedule. Include monitoring instructions and any customer test specification.

Start with our EMC & RF Client Information Sheet to describe the equipment and test configuration. For specialist applications, use our medical EMC preparation checklist or automotive EMC preparation checklist for those applications.

Testing Evidence for Your Target Markets

The required route depends on the product and destination. Stancer supports applicable EMC testing and technical documentation for FCC requirements, ISED requirements, CE marking and VCCI conformity.

Radio, electrical safety and other product requirements are identified separately where relevant. A test report documents the agreed evaluation; certification or approval proceeds through the appropriate process. See global market access support.

EMC Testing: Your Questions Answered

What is electromagnetic compatibility testing?

Electromagnetic compatibility testing evaluates the disturbances a product emits and its ability to function when exposed to electromagnetic disturbances. The applicable product standards define the emissions limits, immunity test levels and performance criteria. The test program depends on the equipment, intended environment and target markets.

What determines EMC testing cost?

EMC testing cost depends on the applicable standards, number of tests, operating modes, ports, sample configurations and time needed for setup and functional monitoring. Bulky equipment, special power arrangements and troubleshooting can affect the program. Send your product specifications and target markets for a project-specific EMC testing quote; any design changes and retesting are agreed separately.

Which EMC standard applies to my product?

That depends on the product category, intended environment and target markets. Send those details and any customer specification so we can determine the relevant product standard and basic methods.

What is the difference between emissions and immunity?

Emissions concern disturbances produced by the equipment. Immunity concerns its response to applied disturbances. The applicable product requirements determine which evaluations are needed.

Is pre-compliance testing the same as formal testing?

No. Pre-compliance supports design investigation and troubleshooting. Formal testing follows the agreed compliance program and produces the corresponding documented results.

Can you test bulky or high-current equipment?

We review the proposed equipment against access, mass, supply and measurement requirements. Available setups include EUT capability up to 200 A, three-phase; chamber access and clearance are confirmed before booking.

Do wireless products need both EMC and RF testing?

They may. Host electronics and radio functions can have different requirements. We coordinate the applicable evaluations within the proposed program.

What happens if the equipment fails a test?

We document the result and can investigate the response with your engineering team. Any changes and retesting are agreed before proceeding, with the tested configuration recorded.

Plan Your EMC Testing with Stancer

Send your product details and destination markets. Our engineers will help define the setup, test sequence and documentation for your program.

Request an EMC Testing Quote Review Our Scope

Prepare for Your EMC or RF Test

Complete our Client Information Sheet before testing. It captures your target markets, product details, power requirements, interfaces, operating modes and monitoring arrangements so our team can plan the assessment.

What to Prepare Before Testing

Send the completed form to info@stancermtl.com. Our technical team will confirm the sample configurations and test requirements for your product.

Plan your testing

Discuss your testing requirements

Tell us about your product and target markets. Our technical team will help clarify the testing scope and prepare a tailored quotation.

Optional. One PDF file, maximum 10 MB.

Required fields are marked with *.